Collections 4 2 – organize your desktop icons shortcut. Notifier SFP-5UD is a five zone conventional fire control panel has features normally found in more expensive addressable systems. The MS-5UD-3 is fully programmable via built-in keypad and 80 character LCD display, so you do not need an external programmer. The SFP-5UD is a five-zone fire alarm control panel for small to medium-sized commercial, industrial & institutional buildings. Find out more. 3d building construction software. Viking magick chants pdf. Microsoft flight simulator 2017. MS-5UD & MS-10UD Series Manual — P/N 52626:C7 6/12/2018 3 Installation Precautions Adherence to the following will aid in problem-free installation with long-term reliability: WARNING - Several different sources of power can be con-nected to the fire alarm control panel. Disconnect all sources of power before servicing. Istat pro mac crack. istat menus crack for mac. Omnigraphsketcher 1 2 4.
Honeywell Notifier Sfp-5ud Manual
See our full line catalog or visit www.honeywellcable.com to see our full product listing of low voltage wire and cable. • Thermostat • Electronic Shielded and Unshielded • Fire • Security • Sound • Video • Voice & Data • And Much More!
Genesis Series Cables for NOTIFIER For more information: www.honeywellcable.com Automation and Control Solutions Honeywell Cable & Custom Electronics 7701 95th Street Pleasant Prairie, WI 53158-2716 800-222-0060 www.honeywell.com
L/NTFR2B/D May 2012 © 2012 Honeywell International Inc.
We've Got a Cable for That!
Signaling Line Circuits (SLC)
Notifier
Maximum Loop Resistance
SFP-2402
SFP-2404
SFP-5UD
SFP-10UD
NFW-50
NFW2-100
NFS-320
NFS2-640
NFS2-3030
SFP-2402
SFP-2404
SFP-5UD
SFP-10UD
NFW-50
NFW2-100
NFS-320
NFS2-640
NFS2-3030
40 Ohms
40 Ohms
50 Ohms
50 Ohms
50 Ohms
Recommended Genesis Cable
DIRECTORY
Wire Requirements
Signaling Line Circuits (SLC) ................... Initiating Device Circuits (IDC)................... Notification Appliance Circuits (NAC) ................ Digital Audio Loop ....................... Noti-Fire-Net™ ......................... Honeywell Genesis Series Fire Alarm Cable .............
2 3 4 5 5 6
NEC Article 760• Fire Alarm Systems The scope of this article covers: This includes fire detection and alarm notification, guard's tour, sprinkler waterflow and sprinkler supervisory systems • Circuits controlled and powered by the fire alarm system including circuits for the control of a building system's safety functions, elevator
Gen. Purpose FPL
Riser FPLR
Plenum FPLP
18 AWG/Shielded
3,225 (983)
4202
4402
4602
16 AWG/Shielded
4,875 (1,486)
4206
4406
4606
14 AWG/Shielded
8,000 (2,438)
4208
4408
4608
12 AWG/Shielded
10,000 (3,048)
4210
4410
4610
40 Ohms 18 AWG/Unshielded
3,225 (983)
4106
4306
4506
16 AWG/Unshielded
4,875 (1,486)
4111
4311
4511
14 AWG/Unshielded
8,000 (2,438)
4113
4313
4513
12 AWG/Unshielded
10,000 (3,048)
4115
4315
4515
18 AWG/Shielded
3,700 (1,127.6 m)
4202
4402
4602
12 AWG/Shielded
5,000 (1,524 m)
4210
4410
4610
4106
4306
4506
18 AWG/Unshielded • Installation of wiring and equipment of fire alarm systems including all circuits controlled and powered by the fire alarm system.
Distance in Feet (m)
Maximum Loop Resistance
3,700 (1,127.6 m) 50 Ohms
16 AWG/Unshielded
6,000 (1,828.8 m)
4111
4311
4511
14 AWG/Unshielded
9,500 (2,895.6 m)
4113
4313
4513
12 AWG/Unshielded
12,500 (3,810 m)
4115
4315
4515
capture, elevator shutdown, door release, smoke doors and damper control, fire doors and damper control and fan shutdown but only where these circuits are powered and controlled by the fire alarm system
Note: Refer to SLC wiring manual for additional details.
NEC Listings for Power Limited Fire Alarm (PLFA) cables • FPL: For general use in buildings • FPLR: For use within buildings in vertical shafts • FPLP: For use in ducts, plenums or other environmental spaces • Direct Burial: For use outdoor or underground sunlight resistant
1
2
Initiating Device Circuits (IDC)
SFP-2402
SFP-2404
SFP-5UD
SFP-10UD
NFW-50
NFW2-100
NFS-320
NFS2-640
NFS2-3030
Notification Appliance Circuits (NAC)
SFP-2402
SFP-2404
SFP-5UD
SFP-10UD
NFW-50
NFW2-100
NFS-320
NFS2-640
NFS2-3030
4
4
2
4
4
4
N/A
2.5 A
3.0 A
2.5 A
2.5 A
1.5 A
1.5 A
N/A
7.0 A
2.5 A
3.0* A
6.0 A
6.0 A
N/A
Number of NACs
Recommended Genesis Cables
AWG
2-Wire Devices
4-Wire Devices
DCR at 75C Maximum Wiring Distance (ft.) Gen. Purpose (Ohms/Mft) FPL
Riser FPLR
Plenum FPLP
18
7.77
6,435
4106
4306
4506
16
4.89
10,225
4111
4311
4511
14
3.07
16,287
4113
4313
4513
12
1.93
25,907
4115
4315
4515
18
7.77
6,435
4107
4307
4507
16
4.89
10,225
4112
4312
4512
14
3.07
16,287
4114
4313
4513
1
Current Per NAC 2.5 A
2.5 A
Maximum Control Panel NAC Current 2.5 A
3.0 A
3.0 A
external power supply only for NFS2-3030 * 6.0A with optional Transformer refer to manual
Maximum Class-B Wiring Distance** (ft.)
Recommended Genesis Cables
0.5 A
1.0 A
1.5 A
2.0 A
2.5 A
Gen. Purpose FPL
Riser FPLR
Plenum FPLP
18 AWG
425
212
142
106
85
4106
4306
4506
16 AWG
675
337
225
169
135
4111
4311
4511
14 AWG
1,075
537
358
269
215
4113
4313
4513
12 AWG
1,710
855
570
427
342
4115
4315
4515
LOAD
Note: Maximum distance based on circuit current of 100mA and loop resistance of 100 Ohms.
backbone
2
AWG
Make no bones about it. Honeywell Genesis® Series Cable is the foundation for quality installations. Even as fire alarm systems grow more advanced, false alarms and failed emergency notification underscore the importance of system reliability.
** Calculations are based on Direct-Current Resistance data for uncoated copper wire, per National Electrical Code (2011 Edition) Table 8, Conductor Properties.
At Honeywell, we know that failure isn't an option and see fire alarm cable for what it really is…the backbone of safety, reliability and your reputation. That's why you need to choose the best cable for the job every time. Honeywell's Genesis Series fire alarm cables are engineered and manufactured with superior workmanship to meet your customer's demands for safe, reliable, and error-free emergency detection and notification. What's more, it's backed by the industry's only 3-for-1 guarantee. When it comes to performance, reliability and service, we've got your back.
Insist on quality and reliability you can trust. Insist on Honeywell Genesis Series Cable. Honeywell Genesis Series Fire Alarm Cables are 100% UL listed and proudly produced in Pleasant Prairie, WI USA. *See website for details. For more information please call 1-800-222-0060 or visit www.honeywellcable.com
3
4
Fire Alarm Cables
Digital Audio Loop
Recommended Genesis Cable Cable Description
Distance in Feet (m)
Gen. Purpose FPL
Riser FPLR
Plenum FPLP
18 AWG/2 C, Unshielded
750 (228.6)
4106
4306
4506
18 AWG/4 C, Unshielded
750 (228.6)
4107
4307
4507
18 AWG/1 Pair, Unshielded FPLP/ NYC LL5
450 ft. (121.9)
-
-
5500 (NYC LL4)
Noti-Fire-Net™
AWG
# COND
SOL/STR
GENERAL PURPOSE - FPL LISTED 18 2 SOL 18 4 SOL RISER RATED - FPLR LISTED 18 2 SOL 18 4 SOL PLENUM RATED - FPLP LISTED 18 2 SOL 18 4 SOL
18 AWG SHIELDED DC RESISTANCE (OHMS)
NOM. CAP. (PF/FT)
PART #
6.5 6.5
20 20
4106 4107
6.5 6.5
19 19
4306 4307
6.5 6.5
24 24
4506 4507
16 AWG UNSHIELDED AWG
# COND
SOL/STR
GENERAL PURPOSE - FPL LISTED 16 2 SOL 16 4 SOL RISER RATED - FPLR LISTED 16 2 SOL 16 4 SOL PLENUM RATED - FPLP LISTED 16 2 SOL 16 4 SOL
Cable Description
Data Threshold: All Nodes and/or Repeaters on a Cable Segment
Point-to-Point
Bus Configuration
2 Nodes/ Repeaters
3 to 7 Nodes/Repeaters
High:
1-500
1-100
Low:
500-100
N/A
High:
1-500
1-100
Low:
500-100
N/A
18 AWG/2 C, Shielded
Recommended Genesis Cables Gen. Purpose
4202
16 AWG/2 C, Shielded
4206 High:
1-400
Riser
4402
4406
Plenum
4602
4606
1-100
14 AWG/2 C, Shielded
4208 Low:
400-800
N/A
High:
1-1,400
1-100
24 AWG/3 Pair Cat 3
4932 Low:
1,200-2,000
N/A
High:
1-1,400
1-100
Low:
1,200-2,000
N/A
High:
1-1,400
1-100
24 AWG/4 Pair Cat 3
24 AWG/6 Pair Cat 3 Low:
1,200-2,000
N/A
High:
1-1,400
1-100
24 AWG/4 Pair Cat 5e Low:
1,200-2,000
N/A
High:
1-800
1-100
Low:
800-1,400
N/A
24 AWG/4 Pair Cat 5e
4408
5032
4608
5042
4933
5033
5043
4934
5034
5044
-
5078
-
# COND
SOL/STR
GENERAL PURPOSE - FPL LISTED 14 2 SOL 14 4 SOL RISER RATED - FPLR LISTED 14 2 SOL 14 4 SOL PLENUM RATED - FPLP LISTED 14 2 SOL 14 4 SOL
NOM. CAP. (PF/FT)
PART #
4.2 4.2
20 20
4111 4112
4.1 4.2
20 20
4311 4312
4.2 4.1
27 27
4511 4512
# COND
SOL/STR
GENERAL PURPOSE - FPL LISTED 12 2 SOL RISER RATED - FPLR LISTED 12 2 SOL PLENUM RATED - FPLP LISTED 12 2 SOL
NOM. CAP. (PF/FT)
PART #
2.6 2.6
22 22
4113 4114
2.5 2.5
22 22
4313 4314
2.5 2.5
27 27
4513 4514
5088
GENERAL PURPOSE - FPL LISTED 18 2 SOL 18 4 SOL RISER RATED - FPLR LISTED 18 2 SOL 18 4 SOL PLENUM RATED - FPLP LISTED 18 2 SOL 18 4 SOL
DC RESISTANCE (OHMS)
NOM. CAP. (PF/FT)
PART #
6.5 6.5
42 42
4202 4203
6.5 6.5
42 42
4402 4203
6.5 6.5
68 68
4602 4603
AWG
# COND
SOL/STR
DC RESISTANCE (OHMS)
NOM. CAP. (PF/FT)
PART #
GENERAL PURPOSE - FPL LISTED 16 2 SOL 16 4 SOL RISER RATED - FPLR LISTED 16 2 SOL 16 4 SOL PLENUM RATED - FPLP LISTED 16 2 SOL 16 4 SOL
4.1 4.1
46 46
4206 4207
4.1 4.1
46 46
4406 4407
4.1 4.1
77 77
4606 4607
AWG
# COND
SOL/STR
DC RESISTANCE (OHMS)
NOM. CAP. (PF/FT)
PART #
GENERAL PURPOSE - FPL LISTED 14 2 SOL 14 4 SOL RISER RATED - FPLR LISTED 14 2 SOL 14 4 SOL PLENUM RATED - FPLP LISTED 14 2 SOL 14 4 SOL
2.5 2.5
52 52
4208 4209
2.5 2.5
52 52
4408 4409
2.5 2.5
86 86
4608 4609
NOM. CAP. (PF/FT)
PART #
1.6
22
4115
2.5
22
4315
1.6
30
4515
AWG
# COND
SOL/STR
DC RESISTANCE (OHMS)
NOM. CAP. (PF/FT)
PART #
GENERAL PURPOSE - FPL LISTED 12 2 SOL RISER RATED - FPLR LISTED 12 2 SOL PLENUM RATED - FPLP LISTED 12 2 SOL
1.6
56
4210
1.7
56
4410
1.6
96
4610
Mid. Capacitance Fire Alarm Cables
AWG
-
SOL/STR
12 AWG SHIELDED DC RESISTANCE (OHMS)
MID. CAPACITANCE CABLES - UNSHIELDED
-
# COND
14 AWG SHIELDED DC RESISTANCE (OHMS)
12 AWG UNSHIELDED AWG
AWG
16 AWG SHIELDED DC RESISTANCE (OHMS)
14 AWG UNSHIELDED AWG
ARTICLE•760
18 AWG UNSHIELDED
# COND
SOL/STR
MID. CAPACITANCE CABLES - SHIELDED
DC RESISTANCE (OHMS)
NOM. CAP. (PF/FT)
PART #
RISER RATED - FPLR LISTED
AWG
# COND
SOL/STR
DC RESISTANCE (OHMS)
NOM. CAP. (PF/FT)
PART #
RISER RATED - FPLR LISTED
18
2
SOL
6.3
15
4431
18
2
SOL
6.3
34
4441
16
2
SOL
4.0
17
4432
16
2
SOL
4.0
38
4442
12
2
SOL
1.6
22
4434
14
2
SOL
2.6
41
4443
12
2
SOL
1.6
48
4444
* For complete cable selection, including Direct Burial and NYC LL5 rated cable, see pages 35-44 in the Honeywell Cable and Custom Electronics catalog.
5
All Honeywell fire alarm cables are proudly produced in Pleasant Prairie, WI USA.
6